Volume 20, Issue 10 (1-2018)                   J Arak Uni Med Sci 2018, 20(10): 90-100 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ghatreh Samani F, Nourian A, Farzadi L. Transvaginal Ultrasound Compared with Serum β-hCG Level for Diagnosis of Ectopic Pregnancy in Symptomatic Patients. J Arak Uni Med Sci 2018; 20 (10) :90-100
URL: http://jams.arakmu.ac.ir/article-1-5245-en.html
1- Department of Radiology, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
2- Department of Radiology, Tabriz University of Medical Sciences, Tabriz, Iran , ali_nourian2002@yahoo.com
3- , Department of Obstetrics and Gynecology, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
Abstract:   (21592 Views)
Abstract
Background: Ultrasonography (US) is the most important imaging modality in detecting both intrauterine and ectopic pregnancies. This study aimed to compare serum β-hCG level with Transvaginal Ultrasound in symptomatic patients with ectopic pregnancy.
Materials and Methods: A total of 210 patients with definite diagnosis of ectopic pregnancy were enrolled prospectively. All patients underwent transvaginal US by an experienced radiologist who was blind to the final status of the patient. Serum levels of β-hCG and the time gap between US examination and last menstrual period (LMP) were compared between patients with positive and negative US findings.
Results: US were positive in 194 patients (92.4%) and negative in the remaining 16 patients (7.6%). The two groups were similar in terms of age (median, 31 years vs. 30.5 years, respectively; p=0.57). Both the median time gap between US and LMP (median, 43 days vs. 34 days, p=0.03) and serum level of β-hCG (median, 1027 mIU/ml vs. 172.5 mIU/ml, p<0.001) were significantly higher in patients with positive US findings. Both differences were independent of each other in multivariate analysis. The best discriminative zone was set at a serum β-hCG level of 326 mIU/ml with a sensitivity and specificity of 86.6% and 87.5%, respectively.
Conclusion: According to our findings, both the median serum level of β-hCG and time gap between US and LMP in patients with missed diagnosis of ectopic pregnancy were significantly lower in comparison with correct diagnosis and proposed discriminative zone for serum level of β-hCG in our study is different from the previous studies though further studies are recommended especially in symptomatic patients with suspected ectopic pregnancy.

 
Full-Text [PDF 568 kb]   (2386 Downloads)    
Type of Study: Original Atricle | Subject: General
Received: 2017/07/28 | Accepted: 2017/12/19

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2025 CC BY-NC 4.0 | Journal of Arak University of Medical Sciences

Designed & Developed by : Yektaweb