<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Arak University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشكي اراك</title_fa>
<short_title>J Arak Uni Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jams.arakmu.ac.ir</web_url>
<journal_hbi_system_id>46</journal_hbi_system_id>
<journal_hbi_system_user>journal46</journal_hbi_system_user>
<journal_id_issn>1735-5338</journal_id_issn>
<journal_id_issn_online>2008-644X</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/jams</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<volume>16</volume>
<number>8</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>طراحی سیستم شیلدینگ جیوه در پرتودرمانی با فوتونهای مگاولتاژ</title_fa>
	<title>Design of Mercury Shielding System in Megavoltage Radiation Therapy</title>
	<subject_fa>علوم پایه</subject_fa>
	<subject>Basic Sciences</subject>
	<content_type_fa>پژوهشي اصیل</content_type_fa>
	<content_type>Original Atricle</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;زمینه و هدف&lt;/strong&gt;: در این تحقیق پارامترهای دزیمتریک جیوه برای معرفی آن به عنوان ماده‌ای مناسب جهت تعدیل اشعه در پرتودرمانی بررسی و با سروبند به عنوان رایج ترین ماده مورد استفاده در اکثر مراکز پرتودرمانی، مقایسه شده است. همچنین چندین طراحی برای سیستم شیلدینگ جیوه معرفی و بررسی شده است.&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;مواد و روش ها&lt;/strong&gt;: در این مطالعه تجربی، برای بررسی جیوه به عنوان تعدیل کننده اشعه، فاکتور عبور برای ضخامتهای مختلف جیوه و سروبند در دو انرژی MV6 وMV18 شتابدهنده درمانی اندازه گیری شد. برای اندازه گیری از دزیمتری نسبی بوسیله اتاقکهای یونیزاسیون استفاده گردید. همچنین سیستم تعدیل کننده با استفاده از جیوه برای پرتودرمانی با سطح مقطع های مختلف طراحی شد.&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;یافته ها&lt;/strong&gt;: نتایج حاصل از دزیمتری نشان می دهد، مقادیر عبور اشعه برای هر دو انرژی برای تمام ضخامت های جیوه و سروبند، با افزایش ابعاد میدان به علت زیاد شدن پراکندگی، افزایش می یابد و روند تغییرات فاکتور عبور جیوه با سروبند مشابه است. همچنین استفاده از طراحی نوع دوم با سطح مقطع شش ضلعی توافق خوبی با کانتور بیمار ایجاد می کند.&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;نتیجه گیری&lt;/strong&gt;: بررسی پارامترهای دزیمتری جیوه به صورت تجربی نشان داد که جیوه به علت دارا بودن ویژگیهای فیزیکی و دزیمتری مناسب مانند مایع بودن در دمای معمولی، قدرت جذب، ضریب تضعیف بالا و ... می تواند به عنوان ماده‌ای مناسب برای تعدیل اشعه (در یک سیستم بسته جهت جلوگیری از انتشار بخارات جیوه در محیط) در پرتودرمانی پیشنهاد داده شود.&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify&quot;&gt;&lt;span style=&quot;font-size: 14px&quot;&gt;&lt;span style=&quot;font-family: times new roman&quot;&gt;&lt;strong&gt;&lt;em&gt;Background&lt;/em&gt;&lt;/strong&gt;: In this research dosimetric parameters of mercury was investigated as a radiotherapy modulator and compared with cerrobend as a common beam attenuator material in most radiotherapy centers. Also several designs for mercury shielding system were evaluated. &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;span style=&quot;font-size: 14px&quot;&gt;&lt;span style=&quot;font-family: times new roman&quot;&gt;&lt;strong&gt;&lt;em&gt;Materials and Methods&lt;/em&gt;&lt;/strong&gt;: In this experimental research transmission factor of different thicknesses of cerrobend and mercury at 6MV and 18MV photon beams was measured in order to investigate mercury as a beam modulator. Relative dosimetry was done with ionization chambers and then mercury modulating system for radiotherapy was designed with different cross sections.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;span style=&quot;font-size: 14px&quot;&gt;&lt;span style=&quot;font-family: times new roman&quot;&gt;&lt;strong&gt;&lt;em&gt;Results&lt;/em&gt;&lt;/strong&gt;: The result show that the transmission values increased with field size increment due to increased scatter contribution, for all cerrobend and mercury thicknesses at two energies. The procedure of mercury transmission factor is in agreement with cerrobend transmission factor. The second designed system with hexagonal cross section is in good agreement with patient contour. &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;span style=&quot;font-size: 14px&quot;&gt;&lt;span style=&quot;font-family: times new roman&quot;&gt;&lt;strong&gt;&lt;em&gt;Conclusion&lt;/em&gt;&lt;/strong&gt;: The experimental investigation on mercury dosimetric parameters showed that mercury can be proposed as a modifier in radiotherapy because of its profit properties such as being liquid in room temperature, power of attenuation and …. So mercury can be proposed as a beam modifier (at closed system because of its poison vapor) in radiotherapy. Keywords: beam modifiers, Cerrobend, dosimetry, Mercury&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>تعدیل کننده اشعه, سروبند,  دزیمتری, جیوه</keyword_fa>
	<keyword>Beam modifiers, Cerrobend, Dosimetry, Mercury</keyword>
	<start_page>55</start_page>
	<end_page>65</end_page>
	<web_url>http://jams.arakmu.ac.ir/browse.php?a_code=A-10-2380-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohamad Javad</first_name>
	<middle_name></middle_name>
	<last_name>Tahmasebi Birgani</last_name>
	<suffix></suffix>
	<first_name_fa>محمدجواد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>طهماسبی بیرگانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>4600319475328460044483</code>
	<orcid>4600319475328460044483</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>1-	Department of Medical Physics, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Fatemeh</first_name>
	<middle_name></middle_name>
	<last_name>Seif</last_name>
	<suffix></suffix>
	<first_name_fa>فاطمه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سیف</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>seif@arakmu.ac.ir</email>
	<code>4600319475328460044484</code>
	<orcid>4600319475328460044484</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>2-	Department of Medical Physics, Arak university of Medical Sciences, Arak, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشگاه علوم پزشکی اراک، اراک، ایران </affiliation_fa>
	 </author>


	<author>
	<first_name>Mohamad Reza</first_name>
	<middle_name></middle_name>
	<last_name>Bayatiani</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بیاتیانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>4600319475328460044485</code>
	<orcid>4600319475328460044485</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>2-	Department of Medical Physics, Arak university of Medical Sciences, Arak, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشگاه علوم پزشکی اراک، اراک، ایران </affiliation_fa>
	 </author>


	<author>
	<first_name>Mansour</first_name>
	<middle_name></middle_name>
	<last_name>Zabihzadeh</last_name>
	<suffix></suffix>
	<first_name_fa>منصور</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ذبیح زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>4600319475328460044486</code>
	<orcid>4600319475328460044486</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>1-	Department of Medical Physics, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyed Mohamad</first_name>
	<middle_name></middle_name>
	<last_name>Hosseyni</last_name>
	<suffix></suffix>
	<first_name_fa>سید محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسینی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>4600319475328460044487</code>
	<orcid>4600319475328460044487</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>3-	Department of Oncology, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran</affiliation>
	<affiliation_fa>گروه رادیوتراپی و آنکولوژی، دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
