<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Arak University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشكي اراك</title_fa>
<short_title>J Arak Uni Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jams.arakmu.ac.ir</web_url>
<journal_hbi_system_id>46</journal_hbi_system_id>
<journal_hbi_system_user>journal46</journal_hbi_system_user>
<journal_id_issn>1735-5338</journal_id_issn>
<journal_id_issn_online>2008-644X</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/jams</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1386</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2008</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تاثیر میزان اکسیژن تجویزی در حین بیهوشی بر میزان بروز عفونت زخم در جراحی‌های تمیز- آلوده </title_fa>
	<title>Effect of the administrated oxygen ratio during anesthesia on incidence of wound infection in clean-contaminated surgery</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa></content_type_fa>
	<content_type></content_type>
	<abstract_fa>مقدمه: به رغم تمهیدات به کار رفته هم اکنون عفونت زخم جراحی یکی از عوامل مهم افزایش مورتالیتی وموربیدیتی بیماران و تحمیل هزینه‌های هنگفت بر سیستم بهداشتی –درمانی محسوب می‌گردد. بر اساس مطالعات اخیر به صورت بالینی و آزمایشگاهی، دریافت اکسیژن اضافی حین عمل با مکانیسم افزایش فشار اکسیژن بافتی و در نتیجه بهبود مکانیسم کشتن اکسیداتیو باکتری‌ها، سبب کاهش عونت زخم می‌گردد. این مطالعه با هدف تاثیر میزان اکسیژن تجویزی در حین بیهوشی بر میزان بروز عفونت زخم در جراحی های تمیز- آلوده صورت گرفته است. روش کار: این مطالعه یک کارآزمایی بالینی دو سویه کور است که روش نمونه‌گیری آن تصادفی ساده با استفاده از جدول اعداد تصادفی می‌باشد. 584 نفر که کاندید جراحی‌های کلاس زخم تمیز-آلوده بوده و معیارهای شرکت در مطالعه را داشتند، به طور تصادفی به دو گروه مساوی تقسیم شدند. به یک گروه FIO240 درصد و به گروه دیگر FIO280 درصد حین بیهوشی داده شد. سپس دو گروه در طی یک دوره دو هفته‌ای از نظر علایم عفونت زخم تحت بررسی قرار گرفتند. نتایج: از 292 نفری کهFIO280 درصد دریافت کرده بودند 11نفر(9/3 درصد) و از 292 نفری کهFIO2 40 درصد دریافت نموده بودند 25 نفر(1/8 درصد) دچار عفونت زخم شدند. با احتمال خطای 5 درصد از نوع آلفا، شیوع عفونت زخم در گروهی که اکسیژن با FIO2 بیشتر گرفته بود به طور معنی‌داری از شیوع عفونت در گروهی که اکسیژن با FIO2 کمتر دریافت نموده بود، کمتر بود. نتیجه گیری: این مطالعه همانند مطالعات مشابه، موید اثر مثبت اکسیژن اضافی حین عمل در کاهش عفونت زخم در جراحی‌های تمیز آلوده است. بنابر این با توجه به بدون عارضه، کم هزینه و موثر بودن این روش در کاهش عفونت زخم برای بیمار، تجویز اکسیژن اضافی حین اعمال جراحی تمیز-آلوده توصیه می‌گردد. </abstract_fa>
	<abstract>Introduction: Despite different methods implemented, surgical wound infection is still an important cause of mortality and morbidity of patients which impose a considerable cost on health care system. According to recent data, administration of supplemental oxygen during operation can reduce the risk of wound infection due to increased tissue oxygenation and therefore better elimination of bacteria by oxidative killing. This study is done to investigate the effect of administered oxygen ratio on the incidence of wound infection in clean-contaminated surgery. Materials and Methods: This is a double blind clinical trial. 584 patients from both sexes between 18 to 60 years old, who were condidated for clean-contaminated surgery were divided into two equal groups randomly. One recived 80% and the other 40% FIO2 during anesthesia. The frequency of wound infection between the two groups was assessed during a two weeks period. Results: Of patients receiving 80% FIO2, 11 (3.9%) patients, and the group recieving 40% FIO2, 25(8.1%) patients had wound infection (p&lt;0.05). Conclusion: This study similar to previous studies showed the positive effect of supplemental oxygen in decreasing risk of surgical wound infection. Therefore according to the low risk and low cost and effectivness of this method in patients undergone surgery, it is recommended in clean-contaminated surgery. </abstract>
	<keyword_fa>جراحی، عفونت زخم، اکسیژن، بیهوشی</keyword_fa>
	<keyword>Surgery, wound infection, oxygen, anesthesia</keyword>
	<start_page>15</start_page>
	<end_page>20</end_page>
	<web_url>http://jams.arakmu.ac.ir/browse.php?a_code=A-10-246-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammadali</first_name>
	<middle_name></middle_name>
	<last_name>Hesami</last_name>
	<suffix></suffix>
	<first_name_fa>محمدعلی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسامی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mahessami@hotmail.com</email>
	<code>460031947532846008619</code>
	<orcid>460031947532846008619</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Amir reza</first_name>
	<middle_name></middle_name>
	<last_name>Naimi</last_name>
	<suffix></suffix>
	<first_name_fa>امیر رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نعیمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>460031947532846008620</code>
	<orcid>460031947532846008620</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Hamid reza</first_name>
	<middle_name></middle_name>
	<last_name>Biranvand</last_name>
	<suffix></suffix>
	<first_name_fa>حمیدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بیرانو ند</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>460031947532846008621</code>
	<orcid>460031947532846008621</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
