<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Arak University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشكي اراك</title_fa>
<short_title>J Arak Uni Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jams.arakmu.ac.ir</web_url>
<journal_hbi_system_id>46</journal_hbi_system_id>
<journal_hbi_system_user>journal46</journal_hbi_system_user>
<journal_id_issn>1735-5338</journal_id_issn>
<journal_id_issn_online>2008-644X</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/jams</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>16</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه دقت تخمین قدرت لنز داخل چشمی بر اساس طول محوری چشم</title_fa>
	<title>Comparison of the Accuracy of Intraocular Lens Power Calculation Based On the Axial Length of the Eye</title>
	<subject_fa>جراحی</subject_fa>
	<subject>Surgery</subject>
	<content_type_fa>پژوهشي اصیل</content_type_fa>
	<content_type>Original Atricle</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;زمینه و هدف&lt;/strong&gt;: برای تخمین قدرت لنز داخل چشمی مورد نیاز برای جراحی کاتاراکت از بیومتری با امواج مافوق صوت استفاده می‎شود و مهم‌ترین عامل در خطای این تخمین، طول محوری چشم می‎باشد. لذا هدف از این مطالعه، بررسی میزان اختلاف در قدرت انکسار نهایی در بیمارانی که تحت عمل جراحی کاتاراکت به روش فیکواموسیفیکاسیون قرار گرفته‎اند بر اساس طول محور چشم می‎باشد.&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;مواد و روش‎ها&lt;/strong&gt;: در این مطالعه مقطعی-تحلیلی تعداد 446 چشم از خرداد 1389 تا آذر1390 از بیمارانی که در بیمارستان امیرکبیر شهر اراک تحت عمل جراحی کاتاراکت به روش فیکوامولسیفیکاسیون قرار گرفتند، تحت بررسی قرار گرفت. بیومتری تمامی چشم‎ها قبل از عمل جراحی با هدف امتروپ شدن دید بیمار انجام شد. بیماران بر اساس طول محوری چشم به گروه‎های کوچک‎تر از 22، بین 22 تا 5/24، بین 5/24 تا 26 و بزرگ‎تر از 26 میلی‎متر طبقه‎بندی شدند.&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;یافته‎ها&lt;/strong&gt;: بین میانگین قدر مطلق میزان انحراف قدرت انکسار نهایی از صفر بر اساس نوع دستگاه بیومتری از لحاظ آماری اختلاف معنی‎داری وجود نداشت. بیشترین میزان میانگین قدر مطلق انحراف قدرت انکسار نهایی از صفر در گروه چشم‎های میوپ بود که برابر با 17/1±52/1 دیوپتر بود ولی بین میانگین قدر مطلق انحراف قدرت انکسار نهایی از صفر با توجه به طول محوری چشم ارتباط معنی‎داری وجود نداشت(081/0=p).&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;نتیجه‎گیری&lt;/strong&gt;: قدرت تخمین لنز با افزایش طول محوری چشم کاهش می‎یابد ولی قدر مطلق اختلاف میانگین‎ها در دو دستگاه (آلکان و نیدک) معنی‎داری از لحاظ میانگین وجود ندارند.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify&quot;&gt;&lt;span style=&quot;font-size: 14px&quot;&gt;&lt;span style=&quot;font-family: times new roman&quot;&gt;&lt;strong&gt;&lt;em&gt;Background&lt;/em&gt;&lt;/strong&gt;: For calculating intraocular lens (IOL) power required for cataract surgery, ultrasonic biometry is used and the axial length of the eye is the most important error in this estimation. Therefore, the aim of this study is to evaluate the final refractive power based on the axis length of the eye in patients undergoing phacoemulsification cataract surgery. &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;span style=&quot;font-size: 14px&quot;&gt;&lt;span style=&quot;font-family: times new roman&quot;&gt;&lt;strong&gt;&lt;em&gt;Materials and Methods&lt;/em&gt;&lt;/strong&gt;: In this cross-sectional study, from June 2010 till December 2011, 446 eyes which underwent phacoemulsification cataract surgery were investigated. Biometry was performed before cataract surgery to achieve emmetropia in all eyes. Based on the axis length of the eye, patients were classified into four groups: less than 22 mm, 22-24.5 mm, 24.5-26 mm, and more than 26 mm. &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;span style=&quot;font-size: 14px&quot;&gt;&lt;span style=&quot;font-family: times new roman&quot;&gt;&lt;strong&gt;&lt;em&gt;Results&lt;/em&gt;&lt;/strong&gt;: There was not a significant difference in mean absolute value of final refractive power deviation from zero. The highest amount of mean absolute value of final refractive power deviation from zero was in myopia group which was equal to 1.52±1.17 diopter. However, there was not a significant difference in the amounts of mean absolute value of final refractive power deviation from zero according to axial length of the eye (p=0.081).&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;span style=&quot;font-size: 14px&quot;&gt;&lt;span style=&quot;font-family: times new roman&quot;&gt;&lt;strong&gt;&lt;em&gt;Conclusion&lt;/em&gt;&lt;/strong&gt;: With increases in axial length of the eye, intraocular lens power calculation decreases, but the absolute difference of means is not significant in two apparatuses.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>طول محوری, بیومتری, لنز داخل چشمی, نزدیک بینی</keyword_fa>
	<keyword>Axial length eye, Biometry, Intraocular lens, Myopia</keyword>
	<start_page>65</start_page>
	<end_page>70</end_page>
	<web_url>http://jams.arakmu.ac.ir/browse.php?a_code=A-10-270-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Ahmad</first_name>
	<middle_name></middle_name>
	<last_name>Sarvarian</last_name>
	<suffix></suffix>
	<first_name_fa>احمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سروریان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>dr.sarvarian@arakmu.ac.ir</email>
	<code>4600319475328460043779</code>
	<orcid>4600319475328460043779</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Ophthalmology, Arak University of Medical Sciences, Arak, Iran</affiliation>
	<affiliation_fa>گروه چشم پزشکی، دانشگاه علوم پزشکی اراک، اراک، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>