Search published articles


Showing 2 results for Moshtagh

Abdolrahim Sadeghi, Hamidreza Rozati, Minou Golestani, Azadeh Moshtagh, Mozhgan Sadeghi , Zoreh Sari,
Volume 4, Issue 2 (Summer 2001)
Abstract

About  3-5  percent  of  population  suffer  from  mental  retardation  (MR)  mildly  to  severely.  One  of  the  most  common  causes  of  Mr  is  chromosomal  aberrations.  In  this  research, Chromosmal  study  was  performed  for  100  Mental  Retarders (MRS)  by  G-banding  Method. 100  MRS  were  suffering  from  downs  syndromes: 21  cases  with  21  free  Trisomy, 1 case  chromosomal  mosaism  and  residual  case  had  Robertsonian  traslocation  14; 21  also  chromosomal  mosaism.  Other  8  MRS  had  be  structural  aberrations  in  chromosmals  such  as  inversion (3  cases), partial  trisomy (1  case), ring  22  chromosme  (1  case)  and  breakages  in  different  chromosmes  (3  cases).   The  results  showed  that  chromosomal  aberrations  are  frequent  between  Mental  Retarderes  and  the  most  common  chromosomal  aberrations  occure  between  MRS is  21  free  trisomy.

Amad Reza Mohajerani, Negin Moshtaghi, Alireza Susanabadi,
Volume 8, Issue 3 (1-2006)
Abstract

Introduction: One of the most important skills which should be learned and performed by physicians and nurses is the correct method of intubation. Therefore, more attention should be given to such trainings. The main purpose of the recent study is manufacturing and utilization of a detector device for correct intubation which can be used by inexpert staff who are not members of anesthesia team.
Materials and Methods: In a quasi experimental study a detector device was manufactured and utilized for correct intubation. In this research 400 patients undergone surgery, had been chosen for testing the device. Their ages varied from 5-75 years old and they had no chronic obstructive pulmonary disease (COPD), asthma and heart disease. These patients have been generally anesthetized. In all patients the tracheal tube has been placed in esophagus and then immediately in trachea, using the device. The sensitivity of device was evaluated. During the procedure patients, oxygenation was not disturbed.
Results: All 400 intubations were performed succesfuly using the device. In this study using air flow out of lungs, intubation was done successfuly. So the devices, sensitivity was 100%. By a professional the mean time for intubation using this device was 5 seconds, and it,s price was 1000 Rials.
Conclusion: Regarding the results, it seems the device is useful in emergencies and facilitates intubation. This device is cheap and portable and seems to be more useful than other reported devices in determining correctiveness of intratracheal intubation.

Page 1 from 1     

© 2025 CC BY-NC 4.0 | Journal of Arak University of Medical Sciences

Designed & Developed by : Yektaweb